- 重庆中国三峡博物馆中央空调集中控制方案[2012-02-28] 【英文篇名】 China Three Gorges Museum in chongqing central air-conditioning centralized control program【作者中文名】 阳勇;【作者英文名】 Yang Yong(China Three Gorges Museum in Chongqing; Chongqing;【作者单位】 重庆中国三峡博物馆;【文献出处】 制冷与空调(四川), Ref...阅读全文>>
- 地热梯级利用技术在节能省地型住宅供暖工程中的应用[2012-02-28] 本文介绍了利用地热-热泵供暖、温泉洗浴的工程概况,对地热水的梯级利用方案中的关键技术进行了深入地探讨与分析
附件下载阅读全文>>
- 冰箱中空气流场和温度场的有限元模拟[2012-02-28] 使用有限元程序FIDAP7.6,在Karlsruhe大学的IBM/6000SP并行计算机上,对冰箱内部的二维稳态空气流场进行了模拟阅读全文>>
- 热回收技术在食品加工企业制冷系统中的应用的探讨[2012-02-28] 摘要:简要阐述了某食品加工厂原制冷系统的大致情况,对此系统进行了优化设计:在制冷系统中加入一套热回收设备,在不影响制冷效果的前提下,利用制冷系统的余热加热常温水,作为生产和员工的生活热水。分析比较表明,加热回收系统后,可大大减少能耗,对能源和环境的保护效果显著。
关键词:食品加工 制冷系...阅读全文>>
- Simulation and modelling of low energy cooling systems for concrete residential houses[2012-02-28] Simulation and modeling of low energy cooling systems with connection to heating and ventilation in typical Czech concrete residential houses aimed to increase occupancy comfort while decreasing the energy consumption. First will be modeled the current situation, af...阅读全文>>
- 基于S7-300的HVAC系统的研究与实现[2012-02-28] 文献出处:制冷 年份:2010 期数:2
论文摘要:本文阐述了以西门子SIMATIC S7-300 PLC与上位机相结合的控制系统对HVAC系统自动控制功能的实现,从系统设备组成入手,介绍了压力控制和温度控制相结合的系统自动控制功能实现,同时详细阐述了以S7-300为核心控制单元的控制系统的硬件组态过程、软件设...阅读全文>>
- 地源热泵户型蓄冰中央空调的探讨[2012-02-28] 针对目前国内空气源热泵户型中央空调存在COP 值低、机组耗电量大,冬季融霜控制困难、室温波动大,机组无真正的能量调节,单相电机组额定制冷(制热) 量太小,给用户带来不便,以及加剧了城市电网的供需矛盾等问题,提出了地源热泵户型蓄冰中央空调的解决方案,并探讨了双热力膨胀阀,双蒸发器和...阅读全文>>
- 某科技馆冰蓄冷系统经济分析[2012-02-28] 与常规空调相比,冰蓄冷空调系统的初投资大,但如果电价合理,冰蓄冷空调系统运行费用可以节省。本文对某科技馆冰蓄冷空调系统的经济性进行了分析,系统初投资的回收年限基本可以接受。
附件下载...阅读全文>>
- 关于通风气流组织效果评价比较方法的探讨[2012-02-28] 本文对一般的通风气流组织效果的评价方法进行了探讨。从尽量减少污染物对工作人员的侵害的角度提出了通风流组织效果的定量评价指标。从理论上论证了其可行性并明确了各指标的物理意义和应用方法。对室内气流组织效果的定量评价方法作了尝试性的工作。
附件下载...阅读全文>>
- 一种新型水源热泵系统的选型设计[2012-02-28] 根据一种新型的水源热泵系统———双级压缩复叠式热泵系统自身的特点,主要对中冷器的选型设计进行了研究,同时提出了针对该系统的中间温度的计算方法。
附件下载阅读全文>>
- 建筑自然通风中的引风、导风、造风技术[2012-02-28] 今年突如其来的非典流行病,向人们敲响了警钟,非典感染多发生在自然通风不良的场合,防止非典最有效的方法是室内通风。自然通风这项古老的技术,又将焕发它的青春。本文分析了如何通过引风、导风、造风措施获得良好自然通风的原理和方法。
附件下载...阅读全文>>
- 闭式环路水源热泵空调系统在我国应用的评价[2012-02-28] 本文通过对水源热泵空调系统在我国四个城市(广州、上海、北京、哈尔滨)的气象条件下及不同负荷特点的建筑中运行能耗进行综合分析,初步得出水源热泵空调系统在我国应用的评价。
附件下载阅读全文>>
- THE INSTRUMENTAL VARIABLE IDENTIFICATION ON ABSORPTION AND DESORPTION OF BUILDING MATERIALS[2012-02-28] Through establishing single input-single output identification mathematics model for the dynamic moisture performance of building envelopes by materials surface’s air relative humidity input and materials moisture capacity output, the interrelation Z transfer funct...阅读全文>>
- Commitment Analysis on Maximum Ventilation Design Amount in All-around Hotel Buildings[2012-02-28] Referring to reasonable usage of building energy, protection for outside air environment in OA (fresh air) inlet and outside noise environment on the side of main air port, three restrictions were put forward as follows, (1) whole building ventilation volume restric...阅读全文>>
- Weather data and heating-degree days for Saudi Arabia[2012-02-28] We present monthly-average maximum, minimum and mean temperatures and the medians of extreme temperatures for 24 weather stations in Saudi Arabia. Heating-degree days are also given for these locations.
附件下载阅读全文>>
- CFD 技术在百级洁净手术室设计中的应用[2012-02-28] 利用CFD 技术对手术室设计风量进行模拟计算,并校核了室内洁净度,模拟了人员对手术室洁净度的影响,得到了手术室的设计风量.
附件下载阅读全文>>
- 国际大厦常规冷却与海水冷却方案比较[2012-02-28] 结合一个濒海工程实例,具体地分析了常规冷却与海水冷却方案在设备投资、运行费用和占用面积等方面的差异,得出了就该工程而言,海水冷却方案明显优于常规冷却方案的结论,同时指出在前者的实施过程中必须注意的几个问题。
附件下载...阅读全文>>
- 全国主要城市空调设计气象参数查询系统[2012-02-28] 李成乐[1] 朱荣强[2][1]北京航天爱锐科技有限责任公司,北京100076 [2]北京晨光燃气有限公司,北京100176摘 要:利用可视化编程语言Visual C++6.0研制开发了“全国主要城市空调设计气象参数查询系统”,可以查询夏季空调室外计算干球温度、夏季空调室外计算湿球温度、冬季空调室外计算干球温度...阅读全文>>
- 浅析住宅用能量回收新风换气机的应用[2012-02-28] 李敏[1] 于蕾[1] 林豹[1] 田野[2][1]沈阳建筑大学市政与环境工程学院,110168 [2]沈阳建筑大学校办工厂,110168摘 要:通过对住宅用能量回收新风换气机特点的分析,介绍了其在提供新风,节能,空气过滤等方面的优点,同时针对其在当前应用中出现的问题提出解决方案。关键词:能量回收 换气机 节能 显...阅读全文>>
- 如何降低空调水系统主要设备的工作压力[2012-02-28] 在高层建筑空调设计中,为扩大空调水系统竖向分区高度,减少投资,方便运行管理,均力图降低系统所承受的压力。本文介绍了几种降低系统主要设备工作压力的方法,并利用水压图,作了较为明确的阐述。
附件下载...阅读全文>>