- 1999年第一期[2004-11-16] 阅读全文>>
- BUILDING ENVELOPEN MOISTURE CONDENSATION FOLLOWING[2004-11-16] Object of this work is the thermal and moisture performance analysis of building exterior walls, according to the European Standard draft prEN ISO 13788:1997 prepared by Technical committee CEN TC89 . In order to establish design criteria and to evaluate the therma...阅读全文>>
- HYDRAULIC STABILTY ANALYSIS IN HYDRONIC SYSTEMS[2004-11-16] Hydraulic stability is an important criterion to evaluate hydronic networks .In this paper, quantitative definition of hydraulic stability is presented and the calculation method is introduced in detail .To a network, this criterion can be calculated according to th...阅读全文>>
- 1997年第4期[2004-11-16] 阅读全文>>
- MOISTURE CONTROL AND ENERGY CONSERVATION IN EXISTI[2004-11-16] By nature books will deteriorate with time. In an environment with higher temperatures and relative humidities the deterioration process can be accelerated . For example mould will easily grow at a high relative humidity condition, whereas very low humidity will mak...阅读全文>>
- 鸿信大厦通风空调工程设计[2004-11-16] 文章分别从建筑概况、大楼空调设计标准、空调负荷、空调冷热源、空调冷冻水系统、空调风系统、空调冷却水系统、空调自动控制方式、大楼通风与防烟排烟设计方法等几个方面介绍了鸿信大厦通风空调工程设计...阅读全文>>
- 2000年第3期[2004-11-16] 美国思路强调以手术室细菌控制的综合措施减少感染风险,不片面强调净化级别;认为净化只是一种手段,无菌程度才是其控制的目的和结果的体现;强调以经济有效的方法实施手术室洁净送风系统,既然单向流设施不能证明可以有效地降低术后感染率,就不宜推广。美国的标准和丰富实践基于其特定的国情,许多地...阅读全文>>
- 板式间接蒸发冷却器中热湿传递过程的理论解及实验验证[2004-11-16] 板式间接蒸发冷即器(Plate-Type Indirect Evaporagive Cooler)是由许多金属或非金属的薄板两两相隔并相互垂直地流道组成,薄板一般由铝反或聚苯乙烯复合材料制成。水膜在换热器的二次空气侧流道内沿壁面从上向下流动。二次空气从下向上逆向掠过水膜表面;一次空气在换热器的一次空气侧流道内水...阅读全文>>
- 建筑湿过程动态特性研究的系统辨识方法[2004-11-16] 本文简要叙述建筑湿过程研究之重要意义,综述了国内外关于湿状况研究的历史、现状和最新研究成果。提出在建筑湿过程研究中可以借用现代控制理论工具,采用系统辨识方法得到系统动态湿特性表达式。建立了有关理论模型并介绍了辨识的基本方法。...阅读全文>>
- 膨胀水箱容积的计算方法Calculating Method for Sizing Expansion[2004-11-16] 本文作者针对计算膨胀水箱容积中存在的问题,通过理论分析得出了计算膨胀水箱容积,系统水容量的正确公式,并给出了相应的计算表格,方便了设计应用。阅读全文>>
- 1998年第一期[2004-11-16] 本文针对半敞开式大空间建筑的空调问题,以长沙世界之窗中心剧场为实例,运用数值仿真并进行数值试验后,对此类半敞开式大空间建筑的空调问题进行了初步的探讨并提出了影响其空调效果的一些重要因素。 ...阅读全文>>
- EXAMINATION OF THE EFFECT OF ENERGY CONSERVATION B[2004-11-16] The purpose of this study is to investigate whether intermittently stopping air conditioning can decrease the energy consumption. Although it may have certain influence on indoor air quality , to stop air conditioning intermittently is one of the most simple and eff...阅读全文>>
- 1999年第一期[2004-11-16] 阅读全文>>
- FEASIBILITY STUDY OF DESICCANT COOLING IN COMBINED[2004-11-16] Based on system thermal COP and Cooling Capacity (CC) analysis, simulation work is carried out for possible application of solid desiccant cooing system in combined heating, cooling and power system (CHCP). With varied environmental air condition and supplied heat s...阅读全文>>
- 热网控制工程的仿真系统及其应用[2004-11-16] 由于热网控制系统的支撑软件在开发、调试过程中存在许多实际困难,因此开发了这套仿真系统。本文是对此工作的总结,阐述了开发仿真系统的目的、系统的组成部分及仿真的具体方法。最后,作为工程上的一个应用,本文介绍了辽河油田热网控制工程进行仿真的一些具体情况。...阅读全文>>
- 燃油锅炉采暖运行费用的经济分析[2004-11-16] 对燃煤锅炉采暖改为燃油锅炉采暖,冬季运行过程中对燃重油、燃轻油及燃天然气进行了全面的经济分析讨论,提出了燃煤锅炉采暖改为燃油锅炉采暖的运行过程中,燃重油、燃轻油及天然气应注意长年耗资运行费用进行了讨论。...阅读全文>>
- 2000年第3期[2004-11-16] 对上海某6层商场的室内空气品质作了为期4天的现场测试和主观调查。结果表明,该商场存在各层温度分布不均匀、换气量不足等问题。阅读全文>>
- 室内环境品质的综合评价[2004-11-16] 人们对某一室内环境的总体印象是综合多项因素评价的结果。本文以办公室环境为对象,从声、光、热和空气品质四个方面来对室内环境进行了综合评价,利用层次分析法确定了各项的权重,提出了预测不满意百分之比指标PD(Predicted Dissatisfied)及其计算公式,并与已发表的主观评价结果进行了对比。...阅读全文>>
- 热水供热管道的温降及散热量计算[2004-11-16] 本文利用传热及流体力学的基本原理和公式,对国内目前供热运行机制条件下,以热水作为热媒的供热管道因与周围环境存在温差造成的温降和散热量的计算方法进行了研究。重点讨论了热水管内流动状态对管道传热系数和影响,并对不同管径管道的传热系数和单位管长的温降进行了计算,对保温和不保温管道...阅读全文>>
- 2000年第6期[2004-11-16] 讲座了现行自然通风计算方法中存在的问题,分析了室内空气密度空气动力系数和室外风速等参数对热压计算的影响,提出了考虑密度随温度非线性变化与室外风速垂直梯度的计算方法和公式。算例表明,计算参数的不同选择会产生计算结果的较大差异。...阅读全文>>
地址:中国·郑州金水区 热线:13007606916,13223029089/ 0371-60957609
E-Mail:mqlbh2016@126.com,
QQ:9797618
在线客服:
Sitemap
网站地图